A-NPC 인버터를 이용한 2차 전지 충 방전 테스트 장비 설계
Design of charging and discharging test equipment using A-NPC inverter for secondary batteries
- 주제(키워드) Loss analysis of Heating System , A-NPC Inverter , NPC Inverter , Multi Level DC/DC Converter
- 발행기관 아주대학교
- 지도교수 이교범
- 발행년도 2019
- 학위수여년월 2019. 2
- 학위명 석사
- 학과 및 전공 일반대학원 전자공학과
- 실제URI http://www.dcollection.net/handler/ajou/000000028358
- 본문언어 한국어
- 저작권 아주대학교 논문은 저작권에 의해 보호받습니다.
초록/요약
This paper proposes a design method for a secondary battery system using an active-neutral point clamped (A-NPC) inverter. The proposed system consists of a secondary battery, 3-level DC/DC converter, DC-link capacitor, and bi-directional A-NPC inverter, respectively. The conventional neutral point clamped (NPC) inverter has limitation on switching the switching loss of IGBT into a particular element to increase the switching frequency. This paper proposes a modulation method for implementing the A-NPC converter instead of the existing NPC converter to address the loss of the unbalances. The simulation verifies the validity of the analysis results and the validity of the secondary cell charging system by suggesting the analysis results of the IGBT according to the modulation method.
more목차
제 1 장 서론 1
제 2 장 A-NPC AC/DC 변환 4
2.1 기존 NPC 토폴로지 4
2.2 A-NPC 토폴로지 6
2.3 A-NPC 및 NPC의 손실 분석 7
제 3 장 멀티 레벨 DC/DC 변환 12
3.1 3레벨 DC/DC 컨버터 토폴로지 및 변조 방법 12
제 4 장 충 방전 시스템 시뮬레이션 17
4.1 충 방전 시스템 전체 토폴로지 17
4.2 A-NPC 3레벨 인버터 시뮬레이션 20
4.3 DC/DC 3레벨 컨버터 시뮬레이션 24
제 7 장 결론 26
부록 27
참고문헌 28